CONTEC ECG Simulatur Multi-Parametru ECG Pazjent Simulatur MS400
Ippakkjar:Individual Pakkett
Dimension:18.86 cm(L)×12.50 cm(W)×4.32 cm(H)
Weigh: about 1.4kg
Accessaries:Standard aċċessorji 9V/1A(CE) power adapter, an User manual, a packaging box, a plastic packaging.
Deskrizzjoni
CONTEC ECG Simulator Multi-Parameter MS400
MS400 Multiparameter Simulator is a portable device, features in small volume and light weight.
It can simulate accurately 12-}lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP.
U it jista ' ikun ittestjat fi fejn il- monitor huwa użat.






- Issimula 35 tipi ta' arritmija (inkluż Atrial, Ventricular, Premature Beat and Konduzzjoni Difetti) u
pacemaker waveforms (inklużi Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non
Aqbad, Mhux Funzjoni).
- Issimula erba 'kanali IBP dejta.
tipi ta ' apnea data.
- Issimula erba ' tipi ta' temperatura dejta.
- Issimula kwadru mewġ, trijangolu mewġ, impuls mewġa u sine mewġ bi aġġustabbli frekwenza.
- Issimula standard ECG kalibrazzjoni, adult u pedjatriku ECG sinjal.
- ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG
database u definit mill-utent forma ta 'mewġa data maħżuna fi TF karta can be murija minn is-simulatur u esportat
għal it-tagħmir biex tkun ittestjat.
- Kull forma ta 'mewġa jista' ikun muri minn jiżżerżaq il 3.5% 27% 27 TFT touch screen, faċli biex topera.
- Power supply: rechargeable lithium battery or linear adapter, li reduces interferenza.
- Fakultattiv operazzjoni modalitajiet: tasti u touch screen.
Parametri:
ECG
Konvenzjonali: All leads have the same voltage with the II-lead as the the reference
Amplitudni: {{0}}.5,1.0,1.5 and 2.0mV
ECG Rate: 15,20,25,30,40,60,80,100,120,140,160,180
200,220,240,260,280,300,320,340 u 350 BPM
ECG artifacts: 50 u 60 Hz, muskolu, linja bażi u nifs
The elevation of the ST segment: {{0}}.8 to -0.8 mV, the step is 0.1 mV
Disturbi fil- ġilda u fit- tessuti ta
Atrial: Atrial Fib(oħxon), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
Ventricular: Vent Fib (oħxon), Vent Fib (fine), PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
Prematur Beat: Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus, PVC2 RV Focus, PVC2 E RV Focus, R R on T RV Focus, Multifocal PVC
Konduzzjoni Difetti: L-Ewwel Grad Qalb Imblokk, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block
Erba ' IBP Kanali
Il default: 00/00}mmHg
Dynamic IBP(unit: mmHg)
Kanal 1:
Artery: 120/80
Radjali: 120/80
Xellug Ventricle: 120/00
Dritt Ventricle: 25/00
Channel 2:
Artery: 120/80
Radial: 120/80
Xellug Ventricle: 120/00
Dritt Atrium(CVP): 15/10
Dritt Ventricle: 25/00
Pulmonari Artery: 25/10
Pulmonari Wedge: 10/2
Left Atrium: 14/4
Kanal 3:
Artery: 120/80
Radjali: 120/80
Left Ventricle: 120/00
Dritt Atrium(CVP): 15/10
Dritt Ventricle: 25/00
Pulmonari Artery: 25/10
Pulmonary Wedge: 10/2
Xellug Atrium: 14/4
Channel 4:
Auto Swan-Ganz (kull 15 sekondi): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
Man Swan-Ganz: press ENTER key to change every time
Pressjoni Statika Livelli
Kanal 1: 0, 80, 160, 240, 320 u 400mmHg
Kanal 2: 0, 50, 100, 150, 200 u 250mmHg
Kanal 3: 0, 20, 40, 60, 80 u 100mmHg
Kanal 4% 3a P4 binarji il - statiku pressjoni livelli ta ' P3
Respirazzjoni
Respirazzjoni Rata: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 u 150 R/MIN
Impedenza: {{0}}.2, 0.5, 1.0 and 3.0 Ω
Linja bażi impedenza: 500, 1000, 1500, 2000Ω
Apnea: 12 s, 22 s, 32 s
Temperatura
Erbgħa temperatura: 0 degree (32 degree F), 24 degree ( 75 degree F), 37 degree (98.6 degree F), 40 degree (104 degree F)